Boot heating, should check whether the silicone roller turn normal shutdown, it should be noted that setting the sweltering delay is normal, not directly shutdown (sweltering delay is generally set at 40-50 minutes is appropriate);
2, the machine at work, in case of power outages, or other causes sudden shutdown, should be immediately put on gloves, while rotating rubber roll edge to remove it put elsewhere cooling, in order to avoid uneven heating burn silicone roller;
3 replace the rubber roller tight silica, such as silica gel was heated to the desired temperature and then locked and fixed, but not too tight;
4, silicone rollers should usually keep the surface clean, try to avoid the transfer film and other debris from sticking to the roller surface, such as the surface of the existing dirt free cloth plus industrial alcohol surface cleaning. If there is stubborn dirt can be used fine sandpaper.
5, with other printing rollers, the silicone roller in use or storage, not with other hard object (such as a wrench) collision, squeeze the bar; away from corrosion articles;
6, silicone temperature is generally about 190 degrees to the normal transfer, in the case of product transfer qualified, should be to minimize the pressure and temperature of the silicone roller.